Professional stun gun, mosquito swatter, arc lighter, high voltage transformer manufacturer since 1990

The principle of electric - Self-defense equipment net

by:Tianwang     2020-06-20
Check my collect useful 0 + 1 has voted to 0 [ dia n ba ng] Electric locking electric batons, civilian self-defense equipment generally designed stick, similar to the flashlight, commonly known as electric. Principle is the instantaneous high pressure pulse, stun contact biological or lead to a shock, the purpose of self-defense. Chinese name alias rod electric batons, electric shock stick use self-defense, self-defense, riot by using range, civil, police electric profile name: electric principle: by transformer, high voltage pulse instantaneous generation stun contact biological or lead to a shock, the purpose of self-defense. Classification: according to the length is divided into large, medium, portable type; According to the function is divided into single function, multi-functional; According to the using range is divided into, civilian police; You can use the electric one. Internal main structure by the integration of high quality of integrated blocks and rechargeable nimh battery. External main structure is mainly composed of ABS hard glue new light electric cylinder high-pressure self-defense electric batons pressure of injection molding and metal materials, usually in the front of the product has a pair of head, or the number of metal shock back-end switch with electric shock of insurance, according to the electric switch, which can produce a strong shock. 2. Self-defense device with electric shock gangster limbs advisable, gangster lose resistance ability, is not to shock. It is strictly prohibited for children to use, or shock head, heart and other vital organs. 3. Self-defense device please don't put wet place, not in the sun, rain, do not put in high and low temperature environment; Ban on metal objects electric shocks. 4. New factory is in a state of discharge, self-defense should be charged before use, with the with dedicated charger or charge since any plugs line, charging current cannot be too much; Charger can't meet the polarity; In the process of charging and charge shall not be used within five minutes after electric shock function, otherwise it will affect the product life; Charging time at around six to eight hours, or it will shorten the battery life, and even cause the battery blowout, damage to the battery. Storage for a month, should check and charge, more than a month long stored, should be put in a dry, well ventilated room, should be to charge on a monthly basis. Charging should be used in 5 minutes or use the electric shock after illumination, otherwise easy to damage the light bulb. Production principle electric circuit principle of BG1 and BG2 rod, B1 constitute the ac and dc converter, B1 booster after the QL bridge rectifier to C2. BG3, BG4 big multivibrator composed of hollow coefficient, it output pulse triggering thyristor three ct5 conduction. Capacitance C2 by 3 ct5 and B2, B3, B4 primary discharge. And B2, B3, B4 each sub facies series nearly thousands of volts output voltage. When the function selector switch K in 1 location for the use of lighting the torch. Electric production element transformer B1 in medium wave magnet intercept 20 mm and 30 mm long two paragraphs, each wound coil with epoxy resin glue into buccal glyph magnetic ring. Each winding data as shown in figure. Do better with E11 form magnetic core. B2, B3, B4 use commercially available XD type 380 v / 6. 3 v lamp transformer, electric batons, first level used in reverse, the original six. 3 v secondary parallel to make primary, original 380 v junior secondary together. Attention should be paid to the secondary voltage phase in series connection, the output voltage. BG1 and BG2 & beta; As far as possible close to value should be greater than 60, and performance. Using the debug rod to adjust dc ac converter first make B1 secondary voltage above 200 v, connected to 39 k load should not be less than 160 v. After connection of the whole machine, lh-zd ablaze, high-voltage pulse transformer issue & other Pa, pa & throughout; The sound. The voltmeter 咵 between SCR Yang, cathode, electric batons monopoly network, electric meter maximum swing should be close to 150 v. Oscillation period should more than wipe oscillator and C2 charging cycle synchronization, which should be in the C2 when charged multivibrator trigger thyristor pulse arrival. This can be achieved by repeatedly adjust the value of R2, C2 and C3 to balance each other, in order to synchronization, as far as possible in order to obtain the best output. After adjusted the high-voltage pulse frequency in the 60 - minute 120 times. Using the high voltage generator and more than 40000 volt rechargeable batteries produced severe shock, make offenders to produce a strong electric shock feeling, whole body numb, hypodynamia, instantaneous loss of ability to do evil, and the working principle of the high pressure low flow is not cause any harm. When use close to the body or on the other side. Attention is, after all, rod rod structure complexity, unlike bar and spray, so use should pay attention to daily maintenance. Mainly in charge. 1, must be discharge before charging!
Custom message
Chat Online 编辑模式下无法使用
Chat Online inputting...